04 Zone Gas Suppression Panel
₹39,250.00
- Description
- Technical Specification
- Features
- Macromancie Advantage
Description
Fire suppression systems for server rooms and data centers are essential to the server room itself. A fire suppression system will automatically extinguish a fire without the need of human intervention. Fire suppression systems for data centers must be suitable for clean air environments, as server rooms and data centres are mostly occupied by personnel.
The designs standards for Fire suppression systems for server rooms and data centers are carried out with strict guidelines, as the fire suppression agents used can be dangerous if not designed correctly.
Sensitive technologies require special protection. Gaseous extinguishing agents are often an ideal solution. Tailored to the specific application, they fight fires without side effects and without leaving extinguishing agent residues even in areas that can not be reached by sprinklers.
We use environmentally-friendly and natural substances, derived from atmospheric gases as well as environmentally-friendly synthetic gases. The extinguishing effect is based on the replacement of oxygen by the inert gases argon, nitrogen and carbon dioxide as well as by heat extraction through the synthetic gases FM-200 or Co2
- Operating Voltage : AC 220v 50Hz ±10%, DC 24v 1 am
- Operating Temperature : 0°C to 50°C
- Operating Humidity : 95% (non‐condensing)
- Hooter Output : 2 A (24v DC)
- Solenoid valve output : 2 A (24v DC)
- EOL : 4k7 ohm, 1 per zone
- Weight : 5.2 kg
- Construction : 1.8 mm CRCA sheet duly power coated
- Dimension : H 362mm * W 403mm * D 122mm
- Colour : Caramel White
– Fully complies to IS 2189 & tested by ERTL(N)
– Operates on 220V AC,50Hz AC Supply with battery backup & inbuilt charger
– Fire/fault status in unambiguous colored LED indications
– 128 Events logging facility with real time clock and keypad(optional)
– 0-3 minute time delay facility for auto release and manual release
– 2 mode of operation (AUTO/MANUAL) & Auto dialer attachable facility
– Common hooter output with individual zone and cross zone output
– Zone wise fire, open, short LED Indications
– Zone wise hooter output & Relay for free contacts
– External s/w to test each zone fire, open, short status manually
– External s/w for reset, Silence, Lamp test
– Zone isolation facility with zone voltage cutoff
– Mains on, system on, charger on visual indications
– Compatible with all types of fire detectors with max. 25 nos. in each zone
– Two zone with 1 no. flooding module, Four zone with 2 no. flooding module
– Use for various gas release system i.e. Fe 227, INERGEN, CO2, Fm200
– battery low & common fire indications
– 16*2 line dot matrix LCD (20*4 LCD optional)
– Separate monitoring of MRU & MAU
– LCD indication for timer on gas discharge